SPECIALIZED TESTING TECHNOLOGY
Special Solutions
Advanced electrical testing and measurement solutions designed for hazardous environments, high-voltage applications, railway systems, machines and electrical switchboards.
Ex Certified
Multimeter – Intrinsically Safe

The MTX 3297Ex
for the following zones:
IIC (gas) 0, 1 and 2
IIIC (dust) 20, 21 and 22
Mines M1
- MULTIMETER – INTRINSICALLY SAFE (Ex certified) with ATEX/IEC Ex IIC (gas) 0, 1, 2, IIIC (dust) 20, 21, 22 and Mines M1
- VLowZ low-impedance voltage measurement in the presence of "stray" disturbance voltages.
- Low-pass filter for measuring the PWM signal
- 1µV resolution for voltage and 0.01 µA resolution for current
- 60,000-count display resolution
- 100 kHz bandwidth
- Secure terminal strip with clear indication of the connections to avoid any risk of error
- After using the Multimeter in a non-hazardous zone, it is not necessary to wait before using it in an explosive zone
Ex Certified
Intrinsically Safe Insulation Tester
Designed for safe insulation resistance testing in potentially explosive industrial environments.

![Ex Certification Marking: I M2 (M1) Ex ib [ia Ma] I Mb / II 2G Ex ib IIB T4 Gb](/src/assets/ex-cert-marking.png)
Technical Specifications
- ISO 1Ex Ex-proof version
- Designed in accordance with EN 60079-0:2018
- Designed in accordance with EN 60079-11:2012
- Voltage range up to 500 V
- Resistance measurement range from 1 kΩ to 20 GΩ
High-Voltage Testing
Digital Voltage Testers Beyond 1000 V and up to 36 kV AC/DC


- 2 pole testers with precise display of the voltage 1 V up to 1200 V AC / 0,01 up to 1500 V DC in DSP series
- clear LED indicator for dangerous voltage. CAT IV 600 V – VDE certified
- HS series from 6V – 36kV AC/DC in 3 models. Surge voltage tested upto 300kV (HS-11)
- Moulded protective impedance reduces high voltage to harmless value of 5V
- Acoustic warning of dangerous voltage
- Also available Telescopic voltage tester for RAILWAY application
All-in-One Testing
Machine and Electrical Switchboard Testers
WHY carry multiple instruments
WHEN testing can be done in
ONE INSTRUMENT

- Dielectric testing with 5000V AC
- IR testing up to 50G at 1000 V DC
- Continuity testing with 25A AC
- Voltage, Current, PF, Harmonic and power measurement
- Leakage current measurement
- RCD and ELCB checking
- Automatic printing of Pass/Fail sticker
- 2-wire/4-wire continuity, 0.1 A, 0.2 A, 10 A; voltage drop ∆U, 25 A
Measurements performed by CA 6163
Tests according to the regulatory standards like IEC with Auto Script
Technical Enquiry
Need a Specialized Electrical Testing Solution?
Speak with our technical team to identify the correct instrument for hazardous zones, high-voltage testing, railway applications, machines or electrical switchboards.
- Intrinsically safe Ex-certified instruments
- High-voltage testers up to 36 kV
- Railway and OHE voltage testing
- Machine & switchboard all-in-one testing